  • 02.02.12
    eea52929 · Bump patch version` ·
    New PATCH release 02.02.12
    
    Changes since 02.02.11:
        double to float
        EOM bias feedback fix, new configs
        ADCScan: Use correct ADC range (16 bit, not 32)
        ADCScan: Fix peak selection
        ADCScan: Use left-most maximum, not right-most
        ADCScan: Larger range for single-value plots
        ADCScan: Plot old delay value
        EOM bias scan, enabled all PLL scans in parallel
        ADC trigger scan added
        ADC scan fixes, runs
        PLLScan: Average over whole ADC range
        Fix missing include and string copy in log
        Fix log timestamps
        Fix hierarchy of PLL control registers
        Re-add ADC scan device
        Fix typos
        ADCScan: Wait after board reset after scan setup
        ADCScan: Readback check for all ADCs
        compact samples array to special length
        added logging function with timestamp
        added compacted arrival time arrays, minor fixes
        Test data: Add missing ADC device
        test: Update config for tests
        doocs parameters setup script
  • 02.02.11
    180d5448 · Bump patch version ·
    New PATCH release 02.02.11
    
    Changes since 02.02.10:
         Add ADCDelayScan and PLLBaseScan
         Status: Periodically write sampleFreq and preSamples
         added DUD and ALL
         UserStatistics: Clear the per-sase arrival time
         test: Add missing calibration table for calibration test
         consistency group fix in calib applier, add BCM latency
         feedback strenghtening, calibration no change on empty FLT
         Remove motor device module
  • 02.02.10
    d5baf77e · Bump patch version ·
    New PATCH release 02.02.10
    
    Changes since 02.02.09:
         Test: Add AutomatioModule smoke test
         switch to toroid constant threshold
         toroid array processing change
         Automation: Add module
         CalibrationApplierTest: Use ConnectingDeviceModule
         persistance workaround
         CalibrationApplier: Add basic test
         Toroid: Data is in 4.5MHz pattern, not dense
         feedback toroid to reprocessed data
         momtor feedback reset limit
         feedback alarms
         CalibrationApplier: Fix reset of calibration table
         Fix various clang-tidy warnings
         StatusCollector: PositionScan status changed
         calibration scripts
         added unmodified averaging to quality, stronger position scan cuts
  • 02.02.09
    61420a48 · Bump patch version ·
    New PATCH release 02.02.09
    
    Changes since 02.02.08:
          uint size fix
  • 02.02.08
    471188fe · Bump patch version ·
    New PATCH release 02.02.08
    
    Changes since 02.02.07:
         encoder settle time and offset realignment
         encoder modes and position hold, motor movememnt loop simplified, LLL invalid bit setting
         StatusCollector: Fix connection for feedback and motor
         Re-enable test for status module
         added position scan previsous position, less vervosity to log, fix cut in position scan analysis
         calib file lines +1
  • 02.02.07
    92b7fbe7 · Bump patch version ·
    New PATCH release 02.02.07
    
    Changes since 02.02.06:
         Bump patch version
         encoder drift protection
  • 02.02.06
    5729de6e · Bump patch version ·
    New PATCH release 02.02.06
    
    Changes since 02.02.05:
    * commit 5729de6ed52de25d56e160760b5734e3ffe6ee65
         ODL,PositionScan: Remove range forwarding
         PositionScan: Make sure the ODL is activated
  • 02.02.05
    cbed23bd · Bump patch version ·
    New PATCH release 02.02.05
    
    Changes since 02.02.04:
         Core: Move motor card initialization up
         Fix typo
         Remove debug output for registers
  • 02.02.04
    497ebbd5 · Bump patch version ·
    New PATCH release 02.02.04
    
    Changes since 02.02.03:
        Initlize SDM carrier board
  • 02.02.03
    728a7d38 · Bump patch version ·
    New PATCH release 02.02.03
    
    Changes since 02.02.02:
        - feedback positions decoupled
        - arrival time offset separate
  • 02.02.02
    318bca84 · Bump patch version ·
    New PATCH release 02.02.02
    
    Changes since 02.02.01:
     - Server: Run motor init script warlier in server setup
  • 02.02.01
    458452b1 · Bump patch version ·
    New PATCH release 02.02.01
    
    Changes since 02.02.00:
     - Drop installing obsolete files
  • 02.02.00
    f8d9b01e · Bump minor version ·
    New MINOR release 02.02.00
    
    Changes since 02.01.06:
     - Completely rewritten Feedback module
     - Completely rewritten CalibrationScan
     - Completely rewritten PositionScan
     - Many fixes regarding ODL movement
     - ArrivalTime calibration using the absolute position encoder
     - Removal of libBAM dependency
     - New statistics for experts
     - Statistics per SASE for Users
  • 02.01.06
    461773e6 · Bump patch version ·
    New PATCH release 02.01.06
    
    Changes since 02.01.05:
         ArrivalTime: Use ODL0/1 as the rest of the code
         Feedback: Remove some debug output
         Fix some compiler warnings regarding signesss/shadow
         FeedbackTest: Fix AddRemove test
         arrivaltimequality to pre buffer and stats change
         Feedback: Change control of feedback
         ArrivalTime: Obey number of MP to average
         ArrivalTime: Minimal number of bunches is 2
         ODL: Read-only interface does not need "ready"
         Always send arrival data via ZMQ
         OpticalSwitch: Re-add missing status message
         test data: Add missing property to config
  • 02.01.05
    5b409584 · Bump patch version ·
    New PATCH release 02.01.05
    
    Changes since 02.01.04:
        Port to MathUtils 3.0
        OpticalSwitch: Add missing device connections
        Feedback: Fix inverted lock status
  • 02.01.04
    4837ebdf · Bump patch version ·
    New PATCH release 02.01.04
    
    Changes since 02.01.03:
        Feedback: Fix issue with enabling additional FT
  • 01.19.10
    4c4a045b · Bump patch version ·
    New PATCH release 01.19.10
    
    Changes since 01.19.09:
         Fix DATA_VALID flag for new Feedback
         Don't crash when adding ft to feedback
  • 01.19.09
    0e84dcd9 · Bump patch level ·
    New PATCH release 01.19.09
    
    Changes since 01.19.08:
         Feedback: Change from Per ODL to Per Flattop
         build: Do not install legacy cruft
         Bump patch version
         FMC25_S6.0.WORD_REVISION does not exist anymore
         Filter disabled flattops from ODL for feedback
  • 02.01.03
    fe7ee0be · Bump patch version ·
    New PATCH release 02.01.03
    
    Changes since 02.01.02:
         Feedback: Also evaluate switch settings
         Status: Fix publishing of SIGN_SCALE
         StatusCollector: Let it be triggered by timer
         Feedback: Rename variable to match CS name
         StatusAggregator: Don't get triggered 5 times per MP
         Feedback: Check for changed flattop after run
         Feedback: Actually obey the flattop settings
         Feedback: Select single flattops again
         Core: Fix typo
  • 02.01.02
    8be17532 · Bump patch version ·
    New PATCH release 02.01.02
    
    Changes since 02.01.01:
        tests: Add tests for feedback module
        Feedback: Fix status from Link and MLO
        Feedback: Change criteria to averaging the filtered times
        Feedback: Toroid::hasBeam is per flattop, not bunch
        Feedback: When enabling feedback, log ODL and FT