New PATCH release 02.02.12 Changes since 02.02.11: double to float EOM bias feedback fix, new configs ADCScan: Use correct ADC range (16 bit, not 32) ADCScan: Fix peak selection ADCScan: Use left-most maximum, not right-most ADCScan: Larger range for single-value plots ADCScan: Plot old delay value EOM bias scan, enabled all PLL scans in parallel ADC trigger scan added ADC scan fixes, runs PLLScan: Average over whole ADC range Fix missing include and string copy in log Fix log timestamps Fix hierarchy of PLL control registers Re-add ADC scan device Fix typos ADCScan: Wait after board reset after scan setup ADCScan: Readback check for all ADCs compact samples array to special length added logging function with timestamp added compacted arrival time arrays, minor fixes Test data: Add missing ADC device test: Update config for tests doocs parameters setup script