New PATCH release 02.02.12

Changes since 02.02.11:
    double to float
    EOM bias feedback fix, new configs
    ADCScan: Use correct ADC range (16 bit, not 32)
    ADCScan: Fix peak selection
    ADCScan: Use left-most maximum, not right-most
    ADCScan: Larger range for single-value plots
    ADCScan: Plot old delay value
    EOM bias scan, enabled all PLL scans in parallel
    ADC trigger scan added
    ADC scan fixes, runs
    PLLScan: Average over whole ADC range
    Fix missing include and string copy in log
    Fix log timestamps
    Fix hierarchy of PLL control registers
    Re-add ADC scan device
    Fix typos
    ADCScan: Wait after board reset after scan setup
    ADCScan: Readback check for all ADCs
    compact samples array to special length
    added logging function with timestamp
    added compacted arrival time arrays, minor fixes
    Test data: Add missing ADC device
    test: Update config for tests
    doocs parameters setup script