st_sim Parameters
Experimental parameters class(:class:`pyrost.simulation.STParams`) for the one-dimenional Speckle Tracking scan stores all the parameters and provides additional methods necessary to perform the simulation.
List of experimental parameters:
-
Experimental geometry parameters:
- defocus : Lens' defocus distance [um].
- det_dist : Distance between the barcode and the detector [um].
- step_size : Scan step size [um].
- n_frames : Number of frames.
-
Detector parameters:
- fs_size : Detector's size along the fast axis in pixels.
- ss_size : Detector's size along the slow axis in pixels.
- pix_size : Detector's pixel size [um].
-
Source parameters:
- p0 : Source beam flux [cnt / s].
- wl : Incoming beam's wavelength [um].
- th_s : Source rocking curve width [rad].
-
Lens parameters:
- ap_x : Lens' aperture size along the x axis [um].
- ap_y : Lens' aperture size along the y axis [um].
- focus : Focal distance [um].
- alpha : Third order aberrations ceofficient [rad/mrad^3].
- ab_cnt : Lens' aberrations center point [0.0 - 1.0].
-
Barcode sample parameters:
- bar_size : Average bar's size [um].
- bar_sigma : Bar bluriness width [um].
- bar_atn : Bar's attenuation coefficient [0.0 - 1.0].
- bulk_atn : Barcode's bulk attenuation coefficient [0.0 - 1.0].
- bar_rnd : Bar's coordinates random deviation [0.0 - 1.0].
- offset : Barcode's offset at the beginning and at the end of the scan from the detector's bounds [um].
Note
You can save protocol to an INI file with :func:`pyrost.Protocol.export_ini` and import protocol from INI file with :func:`pyrost.Protocol.import_ini`.
The default parameters are accessed width :func:`pyrost.simulation.parameters`. The parameters are given by:
[exp_geom]
defocus = 4e2
det_dist = 2e6
step_size = 0.1
n_frames = 300
[detector]
fs_size = 2000
ss_size = 1000
pix_size = 55
[source]
p0 = 2e5
wl = 7.29e-5
th_s = 2e-4
[lens]
ap_x = 40
ap_y = 2
focus = 1.5e3
alpha = -0.05
ab_cnt = 0.5
[barcode]
bar_size = 0.1
bar_sigma = 0.01
bar_atn = 0.3
bulk_atn = 0.0
bar_rnd = 0.6
offset = 0
[system]
verbose = False