New MINOR release 07.01.00 Changes since 07.00.10: - Write pulse and beam start/stop registers, as required for BLC (see #5967). - Fix setpoint slopes allowing to exceed setpoint limit (#5221) - Protect OVC window against out-of-range values (#4247) - Fix not obeying the bitmaskForInhibitAlgos (#5668) - Added reference phase monitor (#4922) - Added trigger interval monitor (#5281) - Check phase modulation time constant to be positive (#4669) - Range check for phase modulation stop time (#4196) - Fix regression: server was not working with table lengthes other than 16384 (as e.g. at REGAE) - Changed format of base config by adding a module "Configuration" as a first layer - Added DOOCS backend to linked libraries for the XML generator, so the XML generator can run if the dmap file contains a reference to a doocs device - Elmininated some warnings (was using deprecated API) - Add new required dependency: math-util