New MINOR release 07.01.00

Changes since 07.00.10:

- Write pulse and beam start/stop registers, as required for BLC (see #5967).
- Fix setpoint slopes allowing to exceed setpoint limit (#5221)
- Protect OVC window against out-of-range values (#4247)
- Fix not obeying the bitmaskForInhibitAlgos (#5668)
- Added reference phase monitor (#4922)
- Added trigger interval monitor (#5281)
- Check phase modulation time constant to be positive (#4669)
- Range check for phase modulation stop time (#4196)

- Fix regression: server was not working with table lengthes other than 16384 (as e.g. at REGAE)

- Changed format of base config by adding a module "Configuration" as a first layer

- Added DOOCS backend to linked libraries for the XML generator, so the XML generator can run if the dmap file contains a reference to a doocs device
- Elmininated some warnings (was using deprecated API)
- Add new required dependency: math-util