00.07.00fe244235 · ·
Fix VNA reading and improve plotting - Fix VNA readings -- Load VNA config (and calibration) from file. The *.znxml file has to be prepared in advance and saved on the VNA. It needs to set the VNA to CW mode and single sweep. -- Trigger single sweep and wait for it to complete -- Fix trace definitions -- Fix scpi command for VNA sweep mode -- Frequency and VNA config file are new parameters in .json file - Improve plotting -- Plot output changed to pdf -- CSV file and plot file have the same base name -- Make showing the plot a command line argument. The pdf file is always created. - Add status printout during stable measurements
-
00.05.0057cd9f4f · ·
VNA_dummy returns string of measurments as per trace Features: -simulated_temperature and simulated_humidity changes as per virtual_time -plotting function now plots two subplots for temperature, humidity and magnitude,phase with respect to equilibrium_indicator -Now VNA_dummy doesn't have simulated_measurement_string -get_measurement_string function now returns string of measurements(magnitude and phase)as per trace instead of simulated_measurements_string
-
00.04.00c568b485 · ·
virtual sleep is calling the simulation also for VNA_dummy Features: -VNA_dummy and chamber_dummy uses simulated_values from shared_simulated_state -now climate_chamber_dummy, VNA dummy, Shared_simulated_state has single instance of itselfs -simulation of climate_chamber runs by virtual_time -simulation of VNA now runs by virtual_time Bug_fixes: -shared_simulated_state_file used in chamber_dummy and VNA_dummy to solve Circular import problem
-
00.06.00329c0402 · ·
Working equilibrium_indicator for phase and magnitude Feature: - All parameters has stored in seperate json_file - Phase is in degree, magnitude is in DB - prototype script has seperate functions for data reading and data writing from chamber and VNA - prototype script has 5th flag to show all_measurements are stable - prototype script has seperate class for measurement_data - Now Equilibrium indicator works for all five flags(temperature_stable, humidity_stable, magnitude_stable, phase_stable, measurements_stable) - If measurements are not stable it reapits measurements while rading data - Close chamber correctly even after exceptions Bug_fixes: -Now each plot has its legend -fix stop condition of stability loop
-
00.03.00573fbf06 · ·
First version with dummies Features: - Introduce dummies for the climate chamber and the VNA - Use localhost instead of the real host name to use the dummy - Make the 'read_monitor' function more realistic in chamber dummy - Equilibrium indicator is an integer number representing a bit field - Prototype script can use the vna dummy - make prototype script interruptible -- <ctrl><C> now gravefully quits and closes the socket properly Bug-fixes: - is_temperature_reached and is_humidity_reached work with real chamber
-
00.02.0048344e64 · ·
First complete version of the prototype script - Waits for chamber to reach target point - Waits for a "soaking time" - Reads the VNA Includes equilibrium indicators for temperature and humidity. Phase and magnitude indicators missing. It is just assumes that the soaking time is lonng enough.
-
00.01.0057a34195 · ·
First working version of the prototype script - read and set humidity and temperature - read S-parameters - measurments sequence from config file