01.05.00
New MINOR release 01.05.00 Changes since 01.04.00: - Added missing dots for the suply current and voltage conversion coefficients, which were 0 as a result (was treated as integer). - Make it compile with the latest doocs version
-
01.04.00
New MINOR release 01.04.00 Changes since 01.03.00: - fixed conversion factors for current and voltage monitors - enable permanent readback of setpoint values which can be changed on the firmware side - improved an error message - add port for channel 8
-
01.02.01
Set Button were not reset automatically if the localtion was offline and/or had a read/write error
-
01.01.07
* Release 01.01.07 + Bug - after time out befoire reading the socket info, cleaning buffer + Improvement - output in DOOCS style
-
01.01.06
release 01.01.06 change following properties SUPPLY_MEZZAZINE_CURRENT --> SUPPLY_MEZZANINE_CURRENT LASERDIODE_CURRENT_COEFF_B --> COEFF_LASERDIODE_CURRENT_B LASERDIODE_CURRENT_COEFF_B_NEW_VALUE --> COEFF_LASERDIODE_CURRENT_B_NEW_VALUE LASERDIODE_CURRENT_COEFF_A --> COEFF_LASERDIODE_CURRENT_A LASERDIODE_CURRENT_COEFF_A_NEW_VALUE --> COEFF_LASERDIODE_CURRENT_A_NEW_VALUE FIRMWARE_STATUS_FLAGS --> FIRMWARE_CONTROL_FLAGS FIRMWARE_STATUS_FLAGS_NEW_VALUE --> FIRMWARE_CONTROL_FLAGS_NEW_VALUE FIRMWARE_STATUS_FLAGS_NEW_VALUE_SET --> FIRMWARE_CONTROL_FLAGS_NEW_VALUE_SET FIRMWARE_CONTROL_FLAGS --> FIRMWARE_STATUS_FLAGS
-
00.02.00
last tag removing old software and merging new register branch This tag was renamed from v0.2 to 00.02.00
-
00.01.00
old (frozen) version ldd libraries and server before starting developing new libraries and server This tag was renamed from v0.1 to 00.01.00